• facebook
  • pinterest
  • sns011
  • twitter
  • xzv (2)
  • xzv (1)

Good User Reputation for Finger Joint Traction Table Cpm - Traction Table With Heating System – Yikang

Short Description:


Product Detail

Related Video

Feedback (2)

Our purpose is to fulfill our clients by offering golden company, great price and premium quality for High Frequency Therapy Device , Hand Rehab Equipment , Pain Medical Physiotherapy Equipment , We always welcome new and old customers presents us with valuable advice and proposals for cooperation, let us grow and develop together, and to contribute to our community and staff!
Good User Reputation for Finger Joint Traction Table Cpm - Traction Table With Heating System – Yikang Detail:

Dual channel independent operation, equipped with double neck pull configuration, flexible deployment of treatment resources.

It can be used to heat the neck and waist at the same time of traction. It can automatically identify the heating of neck and waist. The temperature can be adjusted accurately and the therapeutic effect can be improved.

素材1 素材2

Features

1.Dual channel independent operation, equipped with double neck traction configuration, flexible deployment of treatment resources.

2.Warm function: It can heat the neck and waist at the same time of traction, automatically recognize the neck and waist heating, and the temperature can be adjusted accurately to improve the treatment effect.

3.Continuous traction, intermittent traction, main and auxiliary traction.

4.The traction force can be set at 0 to 99KG. And the traction force can be increased or reduced at any time during the traction process without any downtime setting.

5.Automatic compensation: When the real-time value of traction deviates from the set value due to sudden unexpected actions, the traction machine controlled by microcomputer automatically compensates to ensure the constant traction and patient safety.

6.Safety design: double channel, independent emergency stop switch.

7.Set value lock function: It can lock the set traction and traction time without causing the set value to change due to misoperation.

8.Automatic fault detection, indicating faults with different codes, stopping treatment, and normal use after troubleshooting.

Indication

适应症配图

1.Cervical vertebra: cervical spondylosis, dislocation, cervical muscle spasm, intervertebral disc disorders, cervical artery distortion, cervical ligament lesions, cervical disc herniation or prolapse.

2.Lumbar spine: lumbar muscle spasm, lumbar disc herniation, lumbar functional scoliosis, lumbar degenerative osteoarthritis (hypertrophic), acute and chronic lumbar injury caused by lumbar synovial tissue incarceration and facet joint disorders.


Product detail pictures:

Good User Reputation for Finger Joint Traction Table Cpm -
 Traction Table With Heating System – Yikang detail pictures


Related Product Guide:
The Importance Of Medical Devices And Automated Systems For Doctors
Medical Equipment Tax Benefits

We now have many fantastic staff members customers superior at advertising, QC, and working with varieties of troublesome problem within the generation system for Good User Reputation for Finger Joint Traction Table Cpm - Traction Table With Heating System – Yikang, The product will supply to all over the world, such as: Sri Lanka , USA , Germany , Our products are very popular in the word, like South American, Africa, Asia and so on. Companies to "create first-class products" as the goal, and strive to deliver customers with high quality solutions, present high-quality after-sales service and technical support, and customer mutual benefit, create a better career and future!
  • The supplier cooperation attitude is very good, encountered various problems, always willing to cooperate with us, to us as the real God.
    5 Stars By Novia from Uzbekistan - 2015.09.08 17:09
    Reasonable price, good attitude of consultation, finally we achieve a win-win situation,a happy cooperation!
    5 Stars By Barbara from Suriname - 2016.04.08 14:55
    WhatsApp Online Chat !